Description
(Confirming to EN-837-1 or 3 & IS-3624)
| Nominal size | Ø 100 & 150 mm |
| Accuracy | Gauge: ±1% of FS Switching: ±2% of FS |
| Case & Bezel | SS 304 case with Snap Action bayonet lock type bezel (SS 316 Optional) |
| Ingress Protection | IP 65 as per EN 60 529 or IS/IEC 60 529 IP 68 as per IS/IEC 60 529 – Optional |
| Pressure element — Bourdon Tube | SS 316 / SS 316L / SS 316Ti (Monel 400 Optional) (< 100 bar ’C’ shape / ≥ 100 bar helical shape) |
| Over pressure limit | ≤ 100 bar – 125% of FS > 100 bar < 600 bar – 115% of FS > 600 bar < 1600 bar – 110% of FS |
| Movement | SS 304 (SS 316 optional) |
| Socket | SS 304 / SS 316 / SS 316L (Monel 400 Optional) |
| Dial | Aluminium —Pre-coated White with black marking |
| Pointer | Aluminium —Black Finish Center zero / Micro Zero Adjustment |
| Window | Extended Clear Poly Carbonate Hood / Transparent Acrylic |
| Joints | Argon welded |
| Sealing gasket | Neoprene Rubber (EPDM Optional) |
| Blow out protection | Neoprene Rubber (EPDM Optional) On Back of Case |
| Pressure relief | Top of Case with Vent Valve (On Request) |
| Process Connection | 1/4” / 3/8” / 1/2” BSP / NPT / BSPT (Male) M20 X 1.5 (Male), Other Male or Female Connection On Request |
| Permissible temperature | Ambient : -25’C to 65’C Process : Maximum 1000C |
| Type of mounting | Bottom Connection Direct Mounting Back Connection Direct Mounting Bottom Connection Surface Mounting Back Connection Panel Mounting Back Connection Bracket Mounting |
| Pressure range | -30” Hg … 0 … 2500 bar |
| Contact Type —(Internal / External) | Magnetic Snap Action with Silver Nickel Alloy Contact Standard (Palladium Contact Optional) |
| No. of Contact & Configuration | Single ( 1NO, 1NC) / Double (1NO+NC, 1NC+NO, 2NO, 2NC) |
| Contact Rating | 380 V AC/DC, 50 VA, 1 Amp (Standard) / Max. 5 Amp (Optional) |
| Contact Set Point | Between 10 to 90 % of FS |
| Optional Available features | • Customized Scale with different Unit of Measurement or logo • Electrical Contact gauge attached with Diaphragm Seal • Electrical Contact with Differential Pressure Gauge • Electrical Contact with Schaffer or Low Pressure Diaphragm Operated Gauge • Triple / Quadruple Contact • Inductive Contact, Potential Free Contact |